-40%
Geiger Counter Dosimeter Radiation Nuclear Tester Gamma X-ray Sensitive Handheld
$ 43.13
- Description
- Size Guide
Description
HomeBR-6 Geiger Counter Radiation Nuclear Tester Gamma X-ray Handheld Professional
Description
Geiger Counter Beta Gamma X-ray Nuclear Radiation Tube Dosimeter Detector
Features:
Sophisticated Military Grade GM Tube as the Core Sensor.
High Sensitivity,The device comes with built in audible and visual signals for the level of radiation detected.
Wide Measuring Range. It can be used for radiation detection and monitoring both indoor and outdoor, as well as in other similar environments.
Advantages of long life.
Automatic Data Recording.
Portable and Convenient Device
Application:
Material Inspection.
Environmental Test.
Radiology Protection.
Radiopharmaceuticals Screening.
Specification:
1.Can Detect theType of β,γ, x-ray.
2.Sensor Type: GM Tube
3.Energy Range: 20 kev一3.0 mev ≤± 30% (137Cs-)
4.Relative Inherent Error: ≤±10%
5.Sensitivity: 80 cpm/5μsv/(Co-60)
6.Maximum Dose Equivalent: 99.99μsv/h
7.Using the Ambient Temperature: -25℃一+45℃
8.Rative Humidity: ≤95% (+45℃)
9.Power Supply: 2 x AA Batteries(
NOT Included
)
10.Mateiral: ABS
11.Source Type: Real Particle Sound, Alarm Sound, Mute
Instructions
:
1,Power button
ON
to boot, Boot automatically display real-time monitoring interface
2,After the shutdown, press and hold off zero current consumption
3,Triangular start button is used to measure the mean, Natural environment there is background radiation (background radiation) It will fluctuate within a certain range.
4,The top of the screen displays a blue font for the "second" real-time update of the dose rate, which is characterized by large fluctuations, update speed, real-time, is the mean of the middle of the red font display, is a mean dose rate period, when detecting an item or the environment when press the start button (this time can no longer move the tester)
5,Enter the state average measurement will display the measurement results after the end of the trend diagram below presents the average real measurement value of each moment, mean measurement is characterized by high precision, the effective dose equivalent response rate real environment, but the elapsed time is longer,
6,Horn button is used to select the sound source device, each time you press the switch once source.
When the small speaker icon is displayed when the artificial alarm sound (only achieve this status only sound the alarm threshold)
When the mute icon is displayed when that turn off all sources.
7,The scale key (right key) is used to switch the alarm threshold,
Four optional 0.5 / 1.0 /2.0 /5.0
Packing Include:
1X Geiger Counter Nuclear Radiation Detector
On Jan-14-21 at 18:06:08 PST, seller added the following information: