-40%

Hitachi Vortex-90EX SDD Silicon Drift Detector X-Ray Spectrometer EDS XRF

$ 1581.36

Availability: 100 in stock
  • MPN: Vortex-90EX
  • Brand: Hitachi
  • Radiation Detector Type: X-Ray
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Buyer
  • Country/Region of Manufacture: Japan
  • Refund will be given as: Money Back
  • Condition: New
  • Model: Vortex-EX

    Description

    BRAND NEW
    Hitachi Vortex-90EX Silicon Drift Detector (
    SDD)
    for SEM/EDS, X-ray spectroscopy or XRF.
    Tested working. Meets the resolution spec.
    The detector can be used with an SEM for EDS or stand-alone for x-ray spectrometry or XRF.
    Power supply included.
    Manufacturer's page:
    https://www.hitachi-hightech.com/hhs-us/product_detail/?pn=ana-vortex-90ex
    Specifications:
    Name
    Silicon Drift X-Ray Detector Spectrometer
    Type
    Vortex®-90EX
    Overview
    Vortex®-90EX silicon drift X-ray detectors feature active areas between 30 mm
    2
    and 80 mm
    2
    . Vortex®-90EX detectors are produced from high purity silicon using state-of-the-art CMOS production technology. They feature excellent energy resolution (<130 eV FWHM at Mn Kα is typical) and a high count rate capability. At a very short peaing time of 0.1 µs, an output count rate of 900 kcps is achieved. A unique feature of these detectors is their ability to process high count rates with virtually very small loss in energy resolution and minimal peak shift with count rate. The Vortex®-90EX is operated at near room temperature and cooled by a thermoelectric cooler (TEC) and can be cycled as frequently as needed without any degradation in detector performance. Cool down times are typically less than 2 minutes. The Vortex®-90EX X-ray spectroscopy systems include a detector unit and control box which includes power supplies for the detector, TEC and an optional digital pulse processor with PI-SPEC Software. The complete detector also contains a charge-sensitive preamplifier and temperature stabilization system, which eliminates concerns of varying ambient temperature.
    Typical Applications
    X-ray fluorescence (XRF) spectroscopy – both bulk and micro-fluorescence
    Micro XRF (additional sizes available in near future)
    X-ray diffraction (XRD)
    Partical Induced X-ray Emission (PIXE)
    Total Reflection X-ray Fluorescence (TXRF)
    Synchrotron radiation applications
    Process control
    Features
    Extended probe (90 mm)
    Available in 30, 40, 50, 65, 70, 80 mm
    2
    Available in thickness of 0.5 and 1 mm
    Superb energy resolution
    Detector temperature stabilization
    Additional sizes are available under special contracts
    Small and compact package for minimum vibration
    Digital pulse processor (DPP) with PI-SPEC Software
    US Patent Number
    6,455,858
    7,129,501 B2
    Specifications
    Detector
    Material – Silicon Active Area – 30-80 mm
    2
    – Thickness – 0.5 mm and 1 mm
    Window
    Material – Beryllium Thickness – 12.5 and 25 µm (alternatives available)
    Energy Resolution (FWHM) @ 5.9 keV
    @ 1.0 µs Peaking Time 124 eV - 138 eV
    @ 0.5 µs Peaking Time 130 eV - 139 eV
    @ 0.25 µs Peaking Time 135 eV - 148 eV
    @ 0.1 µs Peaking Time 145 eV - 180 eV
    Preamplifier
    Type – Charge sensitive, 1.5 mV/keV Signal polarity – Positive Reset – Electrical, <1 µs duration Rise time – <100 ns
    Cooling
    Thermoelectric
    Power Consumption
    Nominal voltage – 110/230 V (switchable)
    Power supply and detector – 40 W Maximum
    Physical Specifications
    Detector package weight – 950 g Length – 241 mm (90 mm probe)
    Height×Width – 64 mm×64 mm Cable Standard Length – 3 m
    Digital Pulse Processor (DPP)
    PI-SPEC Software (PDF format, 181kBytes)
    Digital Controls
    Gain – 16-Bit DAC Peaking Time – 0.25 - 16 µs Preset Time – Up to 1717s
    Data Output
    Spectrum Size – 1024, 2048 or 4096 channels Channel Size – 10, 20 or 40 eV
    Integral Non-linearity
    0.1% of full-scale output
    Deadtime Correction
    Better than ± 0.5% accuracy from 0 to 120,000 cps at 4 µs peaking time
    Software
    PI-SPEC software
    *
    – Allows user to acquire, manipulate spectra. Pentium III or later with at least 64 MB memory and 30 MB available disk space.
    VTXDLL package
    *
    – Dynamic-Link Library to facilitate host software communication with the DPP. Pentium III or later with at least 64 MB memory and 30 MB available disk space.
    * Requires a standard USB2.0 port