MCA Nuclear Pioneer Multichannel Analyzer Scintillation Gamma Spectrometer Board

$ 343.2

Availability: 25 in stock
  • Item must be returned within: 30 Days
  • Restocking Fee: No
  • Battery: not included
  • Scintillation probe: not included
  • MPN: RH-MCA-4
  • Calibration: IS REQUIRE
  • Package: Electronic board only
  • Country/Region of Manufacture: Israel
  • Return shipping will be paid by: Buyer
  • Brand: RHElectronics
  • Radiation Detector Type: Scintillation Detector
  • All returns accepted: Returns Accepted
  • Condition: Developed and assembled in my Lab. DIY Electronics board only as shown on the photos, without probe, without battery and without enclosure. The MCA must be calibrated by the buyer with their probe. Instruction manual can be downloaded.
  • Refund will be given as: Money Back

    Description

    Unique Sell - MCA ver.4 Nuclear Pioneer Gamma Spectrometer Electronic Board (electronic module only)
    for DIY Gamma Spectroscopy project
    Nuclear Pioneer MCA Multichannel Analyzer Electronic Module only.
    The MCA can work as a robust Gamma Spectrometer and as a Scintillation Counter Survey Meter. It has high count rate performance for spectrum mode and for scintillation search mode.
    The board has regulated high voltage circuit with adjustable output of 600V-1000V postive polarity that allows to connect a NaI(Tl) probe with BNC cable. Probes with high impedance divider of ~50Meg-120Meg are supported. The pulse pre-amplifier set for an optimal gain, however you can re-adjust it if required.
    The MCA can detect Gaussian shape peaks in real-time. It has small library of radionuclides for hobby Gamma Spectroscopy. The counter calculate energy compensated doserate or can subtract previously saved background data file from the spectrum in real-time during spectrum acquisition.
    The package include fully soldered electronic board with BNC connector and encoder. To use the MCA you need to add NaI(Tl) scintillation probe, BNC cable, LiPo battery, CR2032 battery and MicroSD card. Calibration of hardware and software is required to set a correct gain for your NaI(Tl) probe.
    Nuclear Pioneer MCA can work with small and big volume NaI(Tl) crystals probes. You may need to re-adjust high voltage with small screwdriver after connecting the probe to set the total gain of the analog circuit. Pulse pre-amplifier circuit is set for optimal pulse shape and gain, however in some circumstance you may need to re-adjust the pre-amplifier gain ratio (manual is included).
    Channel-to-Energy scale polynomial calibration can be done with selecting a scheme from the menu and simple picking 3-points on spectrum. Automatic calibration of CPS standard deviation for scintillation mode can be triggered from the menu. Other software settings are changed through serial port commands in UART-USB terminal. The MCA has full speed 12MBit/sec USB port for calibration or spectrum data download.
    Any further firmware updates can be done with friendly Arduino Teensy bootloader by connecting USB cable and selecting ready hex file to upload.
    The board has additional 400V high voltage circuit for connecting 400V Geiger Counter. The board has space to install a tiny SBM-21 sensor. Any 400V GM tube is electrically compatible. The GM sensor CPS readings can be used in scintillation mode during prospecting in high radiation areas.
    The MCA unit require to add CR2032 coin battery for date/hour keeping. The MCA unit require LiPo 3.7V rechargable battery for powering. Battery can be charged with USB cable 5V input. The MCA consumes 250mA-350mA current, depending on LCD backlight level settings.
    MCA ver.4 specifications:
    ARM Cortex-M4 microprocessor
    12-bit 4096 channels ADC
    TFT LCD 3.5” 480x320 with adjustable backlight level
    Rotary Encoder for controls
    600V-1000V adjustable high voltage for photomultiplier probe positive polarity
    (NaI(Tl) probe is not included)
    400V high voltage circuit for Geiger Counter connection
    Adjustable gain & pulse shape pre-amplifier for an external photomultiplier probe
    Gamma Spectrometer Mode (tested up to 10.000 CPS)
    Scintillation Counter Mode with PMT and GM Sensor
    Easy Channel to Energy calibration with selectable scheme and channels pick
    Real time background subtract mode for gamma spectrometer
    Real time gaussian peak detection
    Linear or Logarithmic spectrum viewer
    Energy compensated dose rate
    0.30 uSv/h doserate alert and 2-sigma CPS alert in scint.mode
    CPS standard deviation calibration for scint.mode
    Mute / Alert / Clicking in scint.mode
    Spectrum LCD zoom 512-4096 channels
    require Micro SD card for data storage
    RTC (require CR2032 battery for date and time keeping)
    Internal temperature sensor
    Bluetooth BLE module
    (optional, please inquiry before ordering)
    12Mbit USB port for programming, calibration or data transfer
    Easy firmware update via USB and friendly bootloader
    Power supply: require 3.7V LiPo battery, battery current consumption 250mA-350mA
    3.7V LiPo battery USB charger, software low battery alert
    UPC number: 634154871201
    SKU: RH-MCA-4-Module
    The performance of the gamma spectrometer is strictly depending on your NaI(Tl) scintillation probe specifications and hardware/software calibration of the unit.  Please avoid shorting high voltage on BNC socket and do not use hot plug of the probe because HV arcing across the BNC jack can ruin sensitive electronics. Recommended BNC cable part number CT2942-100. Recommended BNC jack for probe is 31-221-RFX.
    Menu description:
    RETURN – return from menu to current working mode display
    RESTART – restart a new spectrum
    SAVE SPECTRUM – will safe CSV file to uSD card with name XXXXXXXX.CSV, For example, 19051207.CSV file from 19 May 12:07 local time
    VIEW SPECTRUM – load CSV file from uSD card
    LCD ZOOM X – change LCD spectrum zoom 512-4096 channels
    LCD SCALE Y – toggle between linear and linear+log scale
    BACKGROUND – set or turn on/off background subtract mode
    UNLOCK CALIBRATION – allows to unlock 3-points channel-to-energy calibration and to select calibration scheme
    SPECTRUM TIME – set time in seconds for spectrum acquisition
    BACKLIGHT – change LCD backlight level
    BLE icon (on/off) – power on/off internal Bluetooth module
    SIGMA icon (on/off) – activate CPS standard deviation calibration for scintillation mode
    MCA icon – toggle gamma spectrometer mode
    SCI icon – toggle scintillation counter mode
    GM Tube icon – toggle internal Geiger Counter circuit (active in SCI mode only)
    You can download the user manual PDF and the latest firmware updates from manufacturer website.
    Lifetime support from the developer! Any further firmware updates for the device can be done with friendly bootloader application and USB cable. Not require a special programmer to upload the firmware.