-40%
Soviet individual dosimeters D-2. 1969. Rare. 1pcs
$ 5.28
- Description
- Size Guide
Description
Good condition. operability not verified. For collection. 1969quite rare. Produced and used for the Navy of the USSR.
Dosimeters D-2 were included in the naval kit KID 6
Combined delivery!!!
The D-2 and D-500 capacitor-type detectors are designed to measure the exposure dose of gamma radiation in the energy range from 300 Kev to 1.25 MeV with a direct reading on the scale of the measuring panel.
The length and capacity of a single capacitor differ. The d-2 detector makes measurements in the range of 0.005-2P, the d-500 detector-in the range of 2-500 p. The range of each type of dosimeter is divided into three sub-bands. Dosimeters D-500 are intended as emergency dosimeters.
When exposed to gamma radiation, the capacitor is charged with the current of the ionization chamber, which is a radiation detector.
The d-2 and D-500 detectors have a cylindrical body, inside of which there is an ionization chamber and two capacitors: a charging and measuring one, located at the ends of the detector. The charging capacitor is used to supply voltage to the ionization chamber and maintain the saturation mode of the chamber. When the detector is irradiated, an ionization current is generated in the chamber, and the measuring capacitor is charged.
The d-2 detector differs from the d-500 detector by the capacity of the measuring capacitor and the volume of the ionization chamber.
In the saturation mode of the ionization chamber, the charge value on the measuring capacitor is directly proportional to the gamma radiation dose and does not depend on the charging voltage.
The capacities of the charging and measuring capacitors are selected so that at radiation doses up to 4P for the d-2 detector and up to 800P for the d-500 detector, the ionization chambers are in saturation mode. If the values of the specified radiation doses are exceeded, the proportionality between the charge on the measuring capacitor and the gamma radiation dose is violated.
The basic measurement error is ± 10 % for the first third and ± 20% for the rest of the scale from the maximum scale value of each sub-band. Additional error due to the "stroke with stiffness" in the range of 0.3-1.25 MeV - no more than ± 20 %.
The d-2 and D-500 detectors are measured using the kid-6 dosimeter, which also determines the charge of the detectors.
Maybe you like
THESE
Shipping:
After receiving payment I ship withing 3 business days!
Delivery:
Standart International Shipping.Delivery in Europe up to 25 days. USA, Canada, Australia up to 15-50 days(sometimes longer depending on the country).
Payment:
Through PayPal.
Return Policy:
You may return the items within 60 days if you are not satisfied. Contact me through E-bay for return instructions.
Feedback:
Customer Satisfaction is my focus. For any reason you are not satisfied with your purchase let us know and we will put in our best effort to resolve the matter. I appreciate your Positive Feedback, and will do the same in return. Do not leave negative feedback without first communicating with me. Please allow max 2 business days for me to response.
THANK YOU FOR VISIT TO MY STORE! If you like any product bought in my store, but it is not in stock. Feel free to ask questions. We will try to find this product for you as soon as possible.
Wish you more interesting purchases!